Cables for Inverter VFD

Cables for Inverter VFD

Cables for Inverter VFD

Low-capacitance VFD cables for inverters, for fixed and mobile installation, used to connect servomotors and motors in frequency inverter drive systems. The low mutual capacitance of the cores and the double shielding allow for low-loss power transfer.

MotionINVERTER VFD 500 CE
BP
MotionINVERTER VFD 550 CE
BP
MotionINVERTER VFD 600 CE UL
BP
MotionINVERTER VFD 650 CE UL
BP
MotionINVERTER VFD 700 UL LISTED
BP
MotionINVERTER VFD 750 UL LISTED
BP
MotionINVERTER VFD 800 UL LISTED PUR
HP

Performance Levels

Basic Performance

Cables for static application or for installations with minimal and infrequent movements, and bending. PVC sheath anti-oil, flame retardant and resistant to most industrial oils. Also suitable for installations in humid areas. The cables are UL/CSA standard (where required) and UL LISTED (where indicated).

Salient Features

  • Temperature: Static: -30 °C / +90 °
  • Bend radius: 10 x O.D.
  • Speed: 180 m/min
  • Acceleration: 2.0 m/sec2
  • Operating cycles: 200,000
Dynamic Performance

Cables for cable chain application. PVC sheath anti-oil, flame retardant and resistant to most industrial oils. Also suitable for installations in humid areas. The cables are UL/CSA standard (where required) and UL LISTED (where indicated).

Salient Features

  • Temperature: Static: -25 °C / +90 °
    Dynamic: -40 °C / +90 °
  • Bend radius: 6.5 x O.D.
  • Speed: 300 m/min
  • Acceleration: 20 m/sec2
  • Operating cycles: 5,000,000
High Performance

Cables for application in high performance cable chains. PUR sheath, halogen-free, flame retardant and resistant to most industrial oils. Also suitable for installations in humid areas. The cables are UL/CSA standard (where required) and UL LISTED (where indicated).

Salient Features

  • Temperature: Static: -40 °C / +90 °
    Dynamic: -40 °C / +90 °
  • Bend radius: 6.5 x O.D.
  • Speed: 600 m/min
  • Acceleration: 60 m/sec2
  • Operating cycles: 10,000,000