MotionWIRE SH

MotionWIRE SH

Dynamic Performance - PVC 0.6 / 1.0 kV
MotionWIRE SH
DP
Dynamic Performance
Speed300 m/min
Bending Radius6.5 x Ø
Acceleration20 N/mm²
Cycles5.000.000
Torsion±30° /1000 mm
Pulling≤ 20 N/mm2

Single core shielded power cables for fixed installation (with limited movement) or mobile chains and machine parts with axial movement. Suitable for dry and/or wet environments. The resistance to oils and industrial fluids is optimized depending on the level of performance. The choice of specific conductors and insulation provides great flexibility by allowing you to choose the product best suited to the final application. The cables are UL / CSA, EAC and follow the DESINA standard.

Operating Voltage 0.6 / 1.0 kV
Temperature Fixed -40 °C / +90 °C
Dynamic -25 °C / +90 °C
Dielectric Strength 4.0 kV x 5 min.
acc.to EN 50395 Cl. 10.3
Insulation Resistance ≥ 1 GΩ x km
acc.to EN 50395 Cl. 8.1
Electrical Resistance IEC 60228 Cl.6
EN 50395 Part. 5
Other Performance Levels

BP Basic Performance

HP High Performance

DATASHEET

details

MotionCables Code OEM Code Formation Outer Diameter Copper Weight Outer Sheath  
CDS09X01UR-G  - (1x6) 7.3 79.0 RAL 7001 PVC TM5
CDS07X01UR-G  (1x10) 8.3 122.0 RAL 7001 PVC TM5
CDS05X01UR-G  (1x16) 9.9 183.0 RAL 7001 PVC TM5
CDS03X01UR-G  (1x25) 11.7 269.0 RAL 7001 PVC TM5
CDS02X01UR-G  (1x35) 13.5 399.0 RAL 7001 PVC TM5
CDSA1X01UR-G  (1x50) 15.9 581.0 RAL 7001 PVC TM5
CDSA2X01UR-G  (1x70) 18.1 766.0 RAL 7001 PVC TM5
CDSA3X01UR-G  (1x95) 20.0 1011.0 RAL 7001 PVC TM5
CDSA4X01UR-G  (1x120) 22.0 1271.0 RAL 7001 PVC TM5
CDSA5X01UR-G  (1x150) 24.5 1711.0 RAL 7001 PVC TM5
CDSB1X01UR-G  (1x185) 27.1 2101.0 RAL 7001 PVC TM5
CDSB2X01UR-G  (1x240) 28.2 2640.0 RAL 7001 PVC TM5
CDSB3X01UR-G  (1x300) 35.0 2970.0 RAL 7001 PVC TM5
CDS03X01UR-N  - (1x25) 11.7 269.0 RAL 9005 PVC TM5
CDS05X01UR-N  - (1x16) 9.9 183.0 RAL 9005 PVC TM5
CDS07X01UR-N  - (1x10) 8.3 122.0 RAL 9005 PVC TM5
Construction Features

Complete datasheet with construction available upon demand

Product's Features
Oil Resistant (0-III)
EN 50363-4-1, UL 1581
Flame Resistant
IEC 60332-1-2; UL VW1; UL FT 1
Good Flexibility
EN 50289-3-9
Mechanical Features
CYCLES BENDING RAD. SPEED ACCELL.
5.000.000 6.5 x Ø 300 m/min 20 N/mm²

Similar Products - Control & Power